Thermal disinfector HYG 5
The complete solution with hygiene package and thermal disinfector.
- 1 program technology
- Preparation on two levels
- Made in Baden-Württemberg
- 12-month statutory warranty, 3-year guarantee in the Power Duo
- In-house service technicians nationwide
Lease-to-own from €112 net/month for the base unit (72-month term; equipment, water treatment, delivery, installation, training and validation extra depending on the offer). Leasing terms
Leasing from 87 € net/month
Leasing conditionsWe come to you, install your thermodisinfector and instruct you on how to use it.
Fully demineralized water sustainably ensures the maximum service life of your devices and instruments.
We arrange the initial validation through one of our accredited partner laboratories and advise you on your processes in advance. We also arrange revalidations and remind you in good time when they are due.
We have developed innovative pump technology and a new water supply system for our HYG 5. Both ensure the cleaning and disinfection of the external surfaces of your instruments. And it ensures the disinfection of all interior spaces of the hollow body instruments used.
The HYG 5 as an under-table or built-in device offers you extremely comfortable loading with the new interior concept. The upper basket is 100 percent extendable and can hold up to 6 kg of medical instruments. In total, the HYG 5 can process three autoclave loads per cycle. This benefits the entire workflow and reduces effort costs.
Our thermal disinfector HYG 5 processes even demanding batches reliably, quickly and safely; even complex hollow bodies. The construction is stable and powerful. Two preparation levels enable greater flexibility and a smooth process. Even when there are high or changing instrument requirements, the HYG 5 delivers full power.
Our proven and popular Oxides ThermoTabs standardize and make your processing process much easier. The dosage and concentration of the cleaning components are consistent and perfectly coordinated. The storage effort is reduced enormously and incorrect dosages are practically eliminated. Simply.
With the IC HotDrying process, instruments dry using the residual heat of the programme. Simply open the door within 15 minutes after the programme ends. This prevents water stains and damp instruments.
The visual inspection is mandatory. With the HYG 5, we make batch release even easier for you: you can then release it directly on the device display. Our software transfers the release to the batch record at the same time.
Safe instrument reprocessing includes legally compliant process documentation with all prescribed parameters. The HYG 5 offers you interfaces to easily read and archive the data via a network connection or USB stick. We provide our IC Printer documentation software for this purpose. In addition, the documentation can be integrated into your existing practice software via other interfaces (Segosoft, DOGma (DIOS)).
Fully demineralized water sustainably ensures the maximum service life of your devices and instruments. For full desalination we offer the WaterDemin 550.
Read more about device-friendly water treatment: Everything you need to know about water treatment.
The IC Touch Control Display of the HYG 5 shows you immediately when the performance of your VE cartridge is exhausted. Alternatively, your batch record provides information about this.
To operate the thermal disinfector HYG 5, you only need:
- Power supply 220–240 V; 50/60 Hz; 16 A, separately fused
- Cold water connection 3/4 inch
- Drain connection DN19
- Demineralised water
| Type designation | HYG 5 |
|---|---|
| Article number | 120 005 |
| Programme duration | approx. 70 minutes (one programme for all loads) |
| Dimensions countertop unit (H x W x D) | 71 x 48.5 x 55 cm (with handle + 4.7 cm) |
| Dimensions undercounter unit incl. base (H x W x D) | 82 x 48.5 x 55 cm (with handle + 4.7 cm) |
| Door projection (A) | 33 cm |
| Wash chamber, max. load space (W x H x D) | 29 x 40 x 42 cm |
| Weight (empty) | 30.4 kg |
| Floor load | approx. 201 N/m² |
| Wash chamber volume | 101 litres |
| Electrical connection | 220–240 V; 50/60 Hz; 16 A, separately fused; 30 mA RCD |
| Max. sound power (cleaning) | approx. 59 dB |
| Heat emission | < 40 °C |
| Ambient temperature | 15–35 °C |
| Relative humidity | 30–60 % |
| Max. installation altitude | 2000 m |
| Installation category | 2 |
| Air pressure | 75–106 kPa |
| Cold water/demineralised water connection | 3/4" |
| Inlet water temperature | 5–45 °C |
| Drain connection | DN19 |
| Water quality | Pre-rinse with tap water of at least drinking water quality (observe drinking water regulations and local requirements). All further programme steps with demineralised or reverse osmosis water. This protects instruments and device from limescale and deposits. |
| Min. water inlet pressure | 50 kPa (0.5 bar) |
| Max. water inlet pressure | 1000 kPa (10 bar) |
| Spray arm rotation | 25 to ≥ 50 rpm |
| Max. waste water temperature | 93 °C |
| Waste water per hour | approx. 20 l (in smaller intervals) |
| Drain pump capacity | max. 15 l/min (volume in drain hose) |
| Length of inlet and drain hoses | inlet hose 2.00 m; drain hose 2.50 m |
| Length of power cable | 1.90 m |
| Internal memory | up to 3000 cycles |
| Interfaces | USB, network (RJ45) |
| Pollution degree (IEC 61010-1) | category 2 |
| Protection class (IEC 60529) | IP20 |
| CE marking | 0297 |
| Standards | DIN EN ISO 15883-1/2, EN 61010-2-040 |
(pdf ,457.79 KB) You will need the safety data sheet for the Oxides Thermo Tabs for your records, please keep them carefully.
(pdf ,357.62 KB) You will need the safety data sheet for the service tabs for your records, please keep them carefully.
(pdf ,18.03 MB)
(pdf ,1.80 MB) Please check the installation requirements for your thermodisinfector carefully and send this document and signed order back to IC Medical.
We have developed innovative pump technology and a new water supply system for our HYG 5. Both ensure the cleaning and disinfection of the external surfaces of your instruments. And it ensures the disinfection of all interior spaces of the hollow body instruments used.
The HYG 5 as an under-table or built-in device offers you extremely comfortable loading with the new interior concept. The upper basket is 100 percent extendable and can hold up to 6 kg of medical instruments. In total, the HYG 5 can process three autoclave loads per cycle. This benefits the entire workflow and reduces effort costs.
Our thermal disinfector HYG 5 processes even demanding batches reliably, quickly and safely; even complex hollow bodies. The construction is stable and powerful. Two preparation levels enable greater flexibility and a smooth process. Even when there are high or changing instrument requirements, the HYG 5 delivers full power.
Our proven and popular Oxides ThermoTabs standardize and make your processing process much easier. The dosage and concentration of the cleaning components are consistent and perfectly coordinated. The storage effort is reduced enormously and incorrect dosages are practically eliminated. Simply.
With the IC HotDrying process, instruments dry using the residual heat of the programme. Simply open the door within 15 minutes after the programme ends. This prevents water stains and damp instruments.
The visual inspection is mandatory. With the HYG 5, we make batch release even easier for you: you can then release it directly on the device display. Our software transfers the release to the batch record at the same time.
Safe instrument reprocessing includes legally compliant process documentation with all prescribed parameters. The HYG 5 offers you interfaces to easily read and archive the data via a network connection or USB stick. We provide our IC Printer documentation software for this purpose. In addition, the documentation can be integrated into your existing practice software via other interfaces (Segosoft, DOGma (DIOS)).
Fully demineralized water sustainably ensures the maximum service life of your devices and instruments. For full desalination we offer the WaterDemin 550.
Read more about device-friendly water treatment: Everything you need to know about water treatment.
The IC Touch Control Display of the HYG 5 shows you immediately when the performance of your VE cartridge is exhausted. Alternatively, your batch record provides information about this.
To operate the thermal disinfector HYG 5, you only need:
- Power supply 220–240 V; 50/60 Hz; 16 A, separately fused
- Cold water connection 3/4 inch
- Drain connection DN19
- Demineralised water
| Type designation | HYG 5 |
|---|---|
| Article number | 120 005 |
| Programme duration | approx. 70 minutes (one programme for all loads) |
| Dimensions countertop unit (H x W x D) | 71 x 48.5 x 55 cm (with handle + 4.7 cm) |
| Dimensions undercounter unit incl. base (H x W x D) | 82 x 48.5 x 55 cm (with handle + 4.7 cm) |
| Door projection (A) | 33 cm |
| Wash chamber, max. load space (W x H x D) | 29 x 40 x 42 cm |
| Weight (empty) | 30.4 kg |
| Floor load | approx. 201 N/m² |
| Wash chamber volume | 101 litres |
| Electrical connection | 220–240 V; 50/60 Hz; 16 A, separately fused; 30 mA RCD |
| Max. sound power (cleaning) | approx. 59 dB |
| Heat emission | < 40 °C |
| Ambient temperature | 15–35 °C |
| Relative humidity | 30–60 % |
| Max. installation altitude | 2000 m |
| Installation category | 2 |
| Air pressure | 75–106 kPa |
| Cold water/demineralised water connection | 3/4" |
| Inlet water temperature | 5–45 °C |
| Drain connection | DN19 |
| Water quality | Pre-rinse with tap water of at least drinking water quality (observe drinking water regulations and local requirements). All further programme steps with demineralised or reverse osmosis water. This protects instruments and device from limescale and deposits. |
| Min. water inlet pressure | 50 kPa (0.5 bar) |
| Max. water inlet pressure | 1000 kPa (10 bar) |
| Spray arm rotation | 25 to ≥ 50 rpm |
| Max. waste water temperature | 93 °C |
| Waste water per hour | approx. 20 l (in smaller intervals) |
| Drain pump capacity | max. 15 l/min (volume in drain hose) |
| Length of inlet and drain hoses | inlet hose 2.00 m; drain hose 2.50 m |
| Length of power cable | 1.90 m |
| Internal memory | up to 3000 cycles |
| Interfaces | USB, network (RJ45) |
| Pollution degree (IEC 61010-1) | category 2 |
| Protection class (IEC 60529) | IP20 |
| CE marking | 0297 |
| Standards | DIN EN ISO 15883-1/2, EN 61010-2-040 |
(application ,14.95 MB)
(application ,457.79 KB) You will need the safety data sheet for the Oxides Thermo Tabs for your records, please keep them carefully.
(application ,357.62 KB) You will need the safety data sheet for the service tabs for your records, please keep them carefully.
(application ,18.03 MB)
(application ,1.80 MB) Please check the installation requirements for your thermodisinfector carefully and send this document and signed order back to IC Medical.